by admin | Nov 29, 2022 | error codes
SE Code: 16.12:10 – Curing System: Temperature sensor 2 failure or not connected. Problem description: Temperature sensor 2. Corrective action: ▲ Restart the printer. ▲ Reseat/replace Temp. sensor 2. If this doesn’t solve the problem call or email one of our... by admin | Nov 29, 2022 | error codes
SE Code: 16.11:10 – Curing System: Temperature sensor 1 failure or not connected. Problem description: Curing Control PCA Sensors cable Temp. sensor 1. 96 Chapter 3 System error codes ENWW. Corrective action: ▲ Restart the printer. 1. Reseat/replace Curing Control... by admin | Nov 29, 2022 | error codes
SE Code: 16.07:03 – Curing system: warm up timeout (uniformity). Problem description: Ambient temperature below 15C, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor. Corrective action: 1. Check if the... by admin | Nov 29, 2022 | error codes
SE Code: 16.05:00 – Curing system: temperature sensor error. Problem description: Curing Control PCA Temperature Sensors Cable Temp. Sensors. Corrective action: ▲ Restart the printer. 1. Run Service “Curing system monitor”. 2. Reseat/replace Curing Control... by admin | Nov 29, 2022 | error codes
SE Code: 16.04:00 – Curing system: low temperature error. Problem description: Ambient temperature below 15C, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor. Corrective action: 1. Check if the...